Additional benefits through reduction of electric charges and
effect of special rates on new renewable energy by
installing solar in shopping malls and housing
Ex) When installing 3kW
3kW x About 3.6 hours (Annual average generating hours) x 365 days
= 3942kWh
Annually about 370,000won +About 180,000won
from discount for new renewable energy + Progressive tax avoidance effect
Current | Revised |
---|---|
10~20% discount of total electric charges according to the self-consumption ratio of new renewable energy (Excepting if self-consumption ratio is less than 20%) |
50% discount of electric charges saved by self-consumption of new renewable energy (Self-consumption X Average unit price during the middle and maximum load time of previous year X 50%) |
A system that imposes power producers
(supplier) with generating units
(excepting new renewable energy generating units)
over a certain size (500MW) a duty to supply more
than a certain percentage out of total energy
production using new renewable energy
Year | 2012 | 2013 | 2014 | 2015 | 2016 | 2017 | 2018 | 2019 | 2020 | 2021 | 2022 | 2023 | After 2024 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Ratio | 2.0 | 2.5 | 3.0 | 3.0 | 3.5 | 4.0 | 4.5 | 5.0 | 6.0 | 7.0 | 8.0 | 9.0 | 10.0 |
Solar generation quantity is sold to KEPCO or
Korea Power Exchange through the payment of price(SMP),
and sellers are granted REC according to the weighted value granted by Korea Energy Agency when they sell to power market.
1 REC is calculated as a unit of 1MW. Accordingly,
{(Monthly total output (kW)x Weighted value)/1000}=REC
(Decimal point rounded off)
ex) In case solar generation unit is
installed on top of a building
(Monthly energy production 1000Kw, Weighted value 1.5)
1000 * 1.5 / 1000 = 1.5REC
(1REC created, 0.5REC accumulated)
Power | Energy Type and Standards | 2013 | 2014 | ||
---|---|---|---|---|---|
Classification | Detailed Standards | Current | After revision | ||
Solar energy | Land (excepting forest land) | Less than 100Kw | 1.2 | Same as current | - |
From 100Kw | 1.0 (Composite) | Same as current | - | ||
Exceeding 3,000kW | 0.7 (Composite) | Same as current | - | ||
Forest land | 0.7~1.2 | 0.7 | Grace period | ||
Building | Less than 3,000kW | 1.5 | Same as current | - | |
Exceeding 3,000kW | 1.0 (Composite) | Same as current | - | ||
Ocean-floating solar | 1.5 | Same as current | - | ||
Self-consumption solar energy | 1.0 | Same as current | - |
As a solar energy generating unit using railings
of apartment or house, it aims to reduce the use of
electrical power system of KEPCO.
The Jo Eun Energy Co., Ltd. 30, Hyeoksinsandan 3-gil, Naju-si, Jeollanam-do, Korea
CEO Cho Guk-seong Business Registration No. 785-81-00527
TEL 1544-8972 FAX 061-807-2242 Email energy8972@naver.com